A snow contract changes how a machine gets used. A skid steer or track loader that ran a bucket all summer is now switching between a bucket, a blower, a pusher and a broom, often in the dark, in the cold, and sometimes by someone who isn't its regular operator.
Most of the trouble happens where the attachment meets the machine. Here's what to check before the contract starts, and what to do at every hookup.
Quick-attach: see it locked
Make sure the locking levers or wedges are fully engaged on both sides every time. Look at them. Don't go by feel, and don't assume. Packed snow and ice on the coupler plate or in the attachment's receiver can stop the wedges from seating, so clear it out before you hook up. If you have a powered quick-attach, check the lock indicator or look at the wedges themselves. Your manual describes how to confirm the attachment is locked. Do it at every hookup, not just the first one of the night.
Hydraulic couplers: clean, capped and pressure off
- Wipe both halves before you connect them. Dirt and water in a coupler go straight into the hydraulic system, and water in a coupler can freeze.
- Cap them when they're disconnected, on the machine and on the attachment.
- Relieve the pressure before you connect or disconnect, the way your manual describes. If a coupler won't go on, there's usually trapped pressure. Don't force it with a hammer.
- Never heat a coupler or hose with a torch.
Hoses get stiff in the cold
Rubber hose stiffens as the temperature drops, and a hose that gets flexed hard in the cold is the one that cracks at the fitting. Look for:
- Covers that are cracked, worn through, or rubbing against the frame.
- Fittings that are weeping.
- Routing through the full range of lift and tilt, so nothing pinches or stretches at the ends of travel.
Check for leaks with a piece of cardboard, never your hand. A pinhole leak under pressure can inject fluid through skin, and that needs a doctor right away, even if it looks minor.
Electrical connectors
Blowers and some other attachments use a multi-pin plug for their controls. Salt and moisture corrode the pins, and a bad connection means a chute that won't turn in the middle of a lot. Keep the plugs clean, use dielectric grease on the pins, and cap them when they're unplugged.
Grease the attachments too
The pivots on the attachments themselves get missed because they're off the machine most of the time. Blower chute and deflector pivots, pusher trip pivots and broom mounts all need grease before the season.
Where the attachments sit
Keep attachments off the ground on blocks or a pallet so they don't freeze in place, and keep the hoses and couplers up off the snow. Park each one in the same spot every time. At three in the morning, nobody should be looking for the blower.
Coupler types, pressure-relief steps and hose specs vary by machine, so let your operator's manual set the procedure.